Server : Apache System : Linux server1.cgrithy.com 3.10.0-1160.95.1.el7.x86_64 #1 SMP Mon Jul 24 13:59:37 UTC 2023 x86_64 User : nobody ( 99) PHP Version : 8.1.23 Disable Function : NONE Directory : /usr/share/mibs/ietf/ |
ALARM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32, Gauge32, TimeTicks, Counter32, Counter64, IpAddress, Opaque, mib-2, zeroDotZero FROM SNMPv2-SMI -- [RFC2578] DateAndTime, RowStatus, RowPointer, TEXTUAL-CONVENTION FROM SNMPv2-TC -- [RFC2579] SnmpAdminString FROM SNMP-FRAMEWORK-MIB -- [RFC3411] InetAddressType, InetAddress FROM INET-ADDRESS-MIB -- [RFC3291] MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF -- [RFC2580] ZeroBasedCounter32 FROM RMON2-MIB; -- [RFC2021] alarmMIB MODULE-IDENTITY LAST-UPDATED "200409090000Z" -- September 09, 2004 ORGANIZATION "IETF Distributed Management Working Group" CONTACT-INFO "WG EMail: disman@ietf.org Subscribe: disman-request@ietf.org http://www.ietf.org/html.charters/disman-charter.html Chair: Randy Presuhn randy_presuhn@mindspring.com Editors: Sharon Chisholm Nortel Networks PO Box 3511 Station C Ottawa, Ont. K1Y 4H7 Canada schishol@nortelnetworks.com Dan Romascanu Avaya Atidim Technology Park, Bldg. #3 Tel Aviv, 61131 Israel Tel: +972-3-645-8414 Email: dromasca@avaya.com" DESCRIPTION "The MIB module describes a generic solution to model alarms and to store the current list of active alarms. Copyright (C) The Internet Society (2004). The initial version of this MIB module was published in RFC 3877. For full legal notices see the RFC itself. Supplementary information may be available on: http://www.ietf.org/copyrights/ianamib.html" REVISION "200409090000Z" -- September 09, 2004 DESCRIPTION "Initial version, published as RFC 3877." ::= { mib-2 118 } alarmObjects OBJECT IDENTIFIER ::= { alarmMIB 1 } alarmNotifications OBJECT IDENTIFIER ::= { alarmMIB 0 } alarmModel OBJECT IDENTIFIER ::= { alarmObjects 1 } alarmActive OBJECT IDENTIFIER ::= { alarmObjects 2 } alarmClear OBJECT IDENTIFIER ::= { alarmObjects 3 } -- Textual Conventions -- ResourceId is intended to be a general textual convention -- that can be used outside of the set of MIBs related to -- Alarm Management. ResourceId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A unique identifier for this resource. The type of the resource can be determined by looking at the OID that describes the resource. Resources must be identified in a consistent manner. For example, if this resource is an interface, this object MUST point to an ifIndex and if this resource is a physical entity [RFC2737], then this MUST point to an entPhysicalDescr, given that entPhysicalIndex is not accessible. In general, the value is the name of the instance of the first accessible columnar object in the conceptual row of a table that is meaningful for this resource type, which SHOULD be defined in an IETF standard MIB." SYNTAX OBJECT IDENTIFIER -- LocalSnmpEngineOrZeroLenStr is intended to be a general -- textual convention that can be used outside of the set of -- MIBs related to Alarm Management. LocalSnmpEngineOrZeroLenStr ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An SNMP Engine ID or a zero-length string. The instantiation of this textual convention will provide guidance on when this will be an SNMP Engine ID and when it will be a zero lengths string" SYNTAX OCTET STRING (SIZE(0 | 5..32)) -- Alarm Model alarmModelLastChanged OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time of the last creation, deletion or modification of an entry in the alarmModelTable. If the number and content of entries has been unchanged since the last re-initialization of the local network management subsystem, then the value of this object MUST be zero." ::= { alarmModel 1 } alarmModelTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmModelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information about possible alarms on the system, and how they have been modelled." ::= { alarmModel 2 } alarmModelEntry OBJECT-TYPE SYNTAX AlarmModelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries appear in this table for each possible alarm state. This table MUST be persistent across system reboots." INDEX { alarmListName, alarmModelIndex, alarmModelState } ::= { alarmModelTable 1 } AlarmModelEntry ::= SEQUENCE { alarmModelIndex Unsigned32, alarmModelState Unsigned32, alarmModelNotificationId OBJECT IDENTIFIER, alarmModelVarbindIndex Unsigned32, alarmModelVarbindValue Integer32, alarmModelDescription SnmpAdminString, alarmModelSpecificPointer RowPointer, alarmModelVarbindSubtree OBJECT IDENTIFIER, alarmModelResourcePrefix OBJECT IDENTIFIER, alarmModelRowStatus RowStatus } alarmModelIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An integer that acts as an alarm Id to uniquely identify each alarm within the named alarm list. " ::= { alarmModelEntry 1 } alarmModelState OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A value of 1 MUST indicate a clear alarm state. The value of this object MUST be less than the alarmModelState of more severe alarm states for this alarm. The value of this object MUST be more than the alarmModelState of less severe alarm states for this alarm." ::= { alarmModelEntry 2 } alarmModelNotificationId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "The NOTIFICATION-TYPE object identifier of this alarm state transition. If there is no notification associated with this alarm state, the value of this object MUST be '0.0'" DEFVAL { zeroDotZero } ::= { alarmModelEntry 3 } alarmModelVarbindIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The index into the varbind listing of the notification indicated by alarmModelNotificationId which helps signal that the given alarm has changed state. If there is no applicable varbind, the value of this object MUST be zero. Note that the value of alarmModelVarbindIndex acknowledges the existence of the first two obligatory varbinds in the InformRequest-PDU and SNMPv2-Trap-PDU (sysUpTime.0 and snmpTrapOID.0). That is, a value of 2 refers to the snmpTrapOID.0. If the incoming notification is instead an SNMPv1 Trap-PDU, then an appropriate value for sysUpTime.0 or snmpTrapOID.0 shall be determined by using the rules in section 3.1 of [RFC3584]" DEFVAL { 0 } ::= { alarmModelEntry 4 } alarmModelVarbindValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The value that the varbind indicated by alarmModelVarbindIndex takes to indicate that the alarm has entered this state. If alarmModelVarbindIndex has a value of 0, so MUST alarmModelVarbindValue. " DEFVAL { 0 } ::= { alarmModelEntry 5 } alarmModelDescription OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-create STATUS current DESCRIPTION "A brief description of this alarm and state suitable to display to operators." DEFVAL { "" } ::= { alarmModelEntry 6 } alarmModelSpecificPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-create STATUS current DESCRIPTION "If no additional, model-specific Alarm MIB is supported by the system the value of this object is `0.0'and attempts to set it to any other value MUST be rejected appropriately. When a model-specific Alarm MIB is supported, this object MUST refer to the first accessible object in a corresponding row of the model definition in one of these model-specific MIB and attempts to set this object to { 0 0 } or any other value MUST be rejected appropriately." DEFVAL { zeroDotZero } ::= { alarmModelEntry 7 } alarmModelVarbindSubtree OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "The name portion of each VarBind in the notification, in order, is compared to the value of this object. If the name is equal to or a subtree of the value of this object, for purposes of computing the value of AlarmActiveResourceID the 'prefix' will be the matching portion, and the 'indexes' will be any remainder. The examination of varbinds ends with the first match. If the value of this object is 0.0, then the first varbind, or in the case of v2, the first varbind after the timestamp and the trap OID, will always be matched. " DEFVAL { zeroDotZero } ::= { alarmModelEntry 8 } alarmModelResourcePrefix OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "The value of AlarmActiveResourceId is computed by appending any indexes extracted in accordance with the description of alarmModelVarbindSubtree onto the value of this object. If this object's value is 0.0, then the 'prefix' extracted is used instead. " DEFVAL { zeroDotZero } ::= { alarmModelEntry 9 } alarmModelRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Control for creating and deleting entries. Entries may be modified while active. Alarms whose alarmModelRowStatus is not active will not appear in either the alarmActiveTable or the alarmClearTable. Setting this object to notInService cannot be used as an alarm suppression mechanism. Entries that are notInService will disappear as described in RFC2579. This row can not be modified while it is being referenced by a value of alarmActiveModelPointer. In these cases, an error of `inconsistentValue' will be returned to the manager. This entry may be deleted while it is being referenced by a value of alarmActiveModelPointer. This results in the deletion of this entry and entries in the active alarms referencing this entry via an alarmActiveModelPointer. As all read-create objects in this table have a DEFVAL clause, there is no requirement that any object be explicitly set before this row can become active. Note that a row consisting only of default values is not very meaningful." ::= { alarmModelEntry 10 } -- Active Alarm Table -- alarmActiveLastChanged OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time of the last creation or deletion of an entry in the alarmActiveTable. If the number of entries has been unchanged since the last re-initialization of the local network management subsystem, then this object contains a zero value." ::= { alarmActive 1 } alarmActiveOverflow OBJECT-TYPE SYNTAX Counter32 UNITS "active alarms" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of active alarms that have not been put into the alarmActiveTable since system restart as a result of extreme resource constraints." ::= { alarmActive 5 } alarmActiveTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmActiveEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Active Alarms entries." ::= { alarmActive 2 } alarmActiveEntry OBJECT-TYPE SYNTAX AlarmActiveEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries appear in this table when alarms are raised. They are removed when the alarm is cleared. If under extreme resource constraint the system is unable to add any more entries into this table, then the alarmActiveOverflow statistic will be increased by one." INDEX { alarmListName, alarmActiveDateAndTime, alarmActiveIndex } ::= { alarmActiveTable 1 } AlarmActiveEntry ::= SEQUENCE { alarmListName SnmpAdminString, alarmActiveDateAndTime DateAndTime, alarmActiveIndex Unsigned32, alarmActiveEngineID LocalSnmpEngineOrZeroLenStr, alarmActiveEngineAddressType InetAddressType, alarmActiveEngineAddress InetAddress, alarmActiveContextName SnmpAdminString, alarmActiveVariables Unsigned32, alarmActiveNotificationID OBJECT IDENTIFIER, alarmActiveResourceId ResourceId, alarmActiveDescription SnmpAdminString, alarmActiveLogPointer RowPointer, alarmActiveModelPointer RowPointer, alarmActiveSpecificPointer RowPointer } alarmListName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The name of the list of alarms. This SHOULD be the same as nlmLogName if the Notification Log MIB [RFC3014] is supported. This SHOULD be the same as, or contain as a prefix, the applicable snmpNotifyFilterProfileName if the SNMP-NOTIFICATION-MIB DEFINITIONS [RFC3413] is supported. An implementation may allow multiple named alarm lists, up to some implementation-specific limit (which may be none). A zero-length list name is reserved for creation and deletion by the managed system, and MUST be used as the default log name by systems that do not support named alarm lists." ::= { alarmActiveEntry 1 } alarmActiveDateAndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS not-accessible STATUS current DESCRIPTION "The local date and time when the error occurred. This object facilitates retrieving all instances of alarms that have been raised or have changed state since a given point in time. Implementations MUST include the offset from UTC, if available. Implementation in environments in which the UTC offset is not available is NOT RECOMMENDED." ::= { alarmActiveEntry 2 } alarmActiveIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A strictly monotonically increasing integer which acts as the index of entries within the named alarm list. It wraps back to 1 after it reaches its maximum value." ::= { alarmActiveEntry 3 } alarmActiveEngineID OBJECT-TYPE SYNTAX LocalSnmpEngineOrZeroLenStr MAX-ACCESS read-only STATUS current DESCRIPTION "The identification of the SNMP engine at which the alarm originated. If the alarm is from an SNMPv1 system this object is a zero length string." ::= { alarmActiveEntry 4 } alarmActiveEngineAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates what type of address is stored in the alarmActiveEngineAddress object - IPv4, IPv6, DNS, etc." ::= { alarmActiveEntry 5 } alarmActiveEngineAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The address of the SNMP engine on which the alarm is occurring. This object MUST always be instantiated, even if the list can contain alarms from only one engine." ::= { alarmActiveEntry 6 } alarmActiveContextName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the SNMP MIB context from which the alarm came. For SNMPv1 alarms this is the community string from the Trap. Note that care MUST be taken when selecting community strings to ensure that these can be represented as a well-formed SnmpAdminString. Community or Context names that are not well-formed SnmpAdminStrings will be mapped to zero length strings. If the alarm's source SNMP engine is known not to support multiple contexts, this object is a zero length string." ::= { alarmActiveEntry 7 } alarmActiveVariables OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of variables in alarmActiveVariableTable for this alarm." ::= { alarmActiveEntry 8 } alarmActiveNotificationID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The NOTIFICATION-TYPE object identifier of the alarm state transition that is occurring." ::= { alarmActiveEntry 9 } alarmActiveResourceId OBJECT-TYPE SYNTAX ResourceId MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the resource under alarm. If there is no corresponding resource, then the value of this object MUST be 0.0." ::= { alarmActiveEntry 10 } alarmActiveDescription OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides a textual description of the active alarm. This text is generated dynamically by the notification generator to provide useful information to the human operator. This information SHOULD provide information allowing the operator to locate the resource for which this alarm is being generated. This information is not intended for consumption by automated tools." ::= { alarmActiveEntry 11 } alarmActiveLogPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "A pointer to the corresponding row in a notification logging MIB where the state change notification for this active alarm is logged. If no log entry applies to this active alarm, then this object MUST have the value of 0.0" ::= { alarmActiveEntry 12 } alarmActiveModelPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "A pointer to the corresponding row in the alarmModelTable for this active alarm. This points not only to the alarm model being instantiated, but also to the specific alarm state that is active." ::= { alarmActiveEntry 13 } alarmActiveSpecificPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "If no additional, model-specific, Alarm MIB is supported by the system this object is `0.0'. When a model-specific Alarm MIB is supported, this object is the instance pointer to the specific model-specific active alarm list." ::= { alarmActiveEntry 14 } -- Active Alarm Variable Table -- alarmActiveVariableTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmActiveVariableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of variables to go with active alarm entries." ::= { alarmActive 3 } alarmActiveVariableEntry OBJECT-TYPE SYNTAX AlarmActiveVariableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries appear in this table when there are variables in the varbind list of a corresponding alarm in alarmActiveTable. Entries appear in this table as though the trap/notification had been transported using a SNMPv2-Trap-PDU, as defined in [RFC3416] - i.e., the alarmActiveVariableIndex 1 will always be sysUpTime and alarmActiveVariableIndex 2 will always be snmpTrapOID. If the incoming notification is instead an SNMPv1 Trap-PDU and the value of alarmModelVarbindIndex is 1 or 2, an appropriate value for sysUpTime.0 or snmpTrapOID.0 shall be determined by using the rules in section 3.1 of [RFC3584]." INDEX { alarmListName, alarmActiveIndex, alarmActiveVariableIndex } ::= { alarmActiveVariableTable 1 } AlarmActiveVariableEntry ::= SEQUENCE { alarmActiveVariableIndex Unsigned32, alarmActiveVariableID OBJECT IDENTIFIER, alarmActiveVariableValueType INTEGER, alarmActiveVariableCounter32Val Counter32, alarmActiveVariableUnsigned32Val Unsigned32, alarmActiveVariableTimeTicksVal TimeTicks, alarmActiveVariableInteger32Val Integer32, alarmActiveVariableOctetStringVal OCTET STRING, alarmActiveVariableIpAddressVal IpAddress, alarmActiveVariableOidVal OBJECT IDENTIFIER, alarmActiveVariableCounter64Val Counter64, alarmActiveVariableOpaqueVal Opaque } alarmActiveVariableIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A strictly monotonically increasing integer, starting at 1 for a given alarmActiveIndex, for indexing variables within the active alarm variable list. " ::= { alarmActiveVariableEntry 1 } alarmActiveVariableID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm variable's object identifier." ::= { alarmActiveVariableEntry 2 } alarmActiveVariableValueType OBJECT-TYPE SYNTAX INTEGER { counter32(1), unsigned32(2), timeTicks(3), integer32(4), ipAddress(5), octetString(6), objectId(7), counter64(8), opaque(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the value. One and only one of the value objects that follow is used for a given row in this table, based on this type." ::= { alarmActiveVariableEntry 3 } alarmActiveVariableCounter32Val OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value when alarmActiveVariableType is 'counter32'." ::= { alarmActiveVariableEntry 4 } alarmActiveVariableUnsigned32Val OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value when alarmActiveVariableType is 'unsigned32'." ::= { alarmActiveVariableEntry 5 } alarmActiveVariableTimeTicksVal OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value when alarmActiveVariableType is 'timeTicks'." ::= { alarmActiveVariableEntry 6 } alarmActiveVariableInteger32Val OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value when alarmActiveVariableType is 'integer32'." ::= { alarmActiveVariableEntry 7 } alarmActiveVariableOctetStringVal OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..65535)) MAX-ACCESS read-only STATUS current DESCRIPTION "The value when alarmActiveVariableType is 'octetString'." ::= { alarmActiveVariableEntry 8 } alarmActiveVariableIpAddressVal OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The value when alarmActiveVariableType is 'ipAddress'." ::= { alarmActiveVariableEntry 9 } alarmActiveVariableOidVal OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The value when alarmActiveVariableType is 'objectId'." ::= { alarmActiveVariableEntry 10 } alarmActiveVariableCounter64Val OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The value when alarmActiveVariableType is 'counter64'." ::= { alarmActiveVariableEntry 11 } alarmActiveVariableOpaqueVal OBJECT-TYPE SYNTAX Opaque (SIZE(0..65535)) MAX-ACCESS read-only STATUS current DESCRIPTION "The value when alarmActiveVariableType is 'opaque'. Note that although RFC2578 [RFC2578] forbids the use of Opaque in 'standard' MIB modules, this particular usage is driven by the need to be able to accurately represent any well-formed notification, and justified by the need for backward compatibility." ::= { alarmActiveVariableEntry 12 } -- Statistics -- alarmActiveStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmActiveStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table represents the alarm statistics information." ::= { alarmActive 4 } alarmActiveStatsEntry OBJECT-TYPE SYNTAX AlarmActiveStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Statistics on the current active alarms." INDEX { alarmListName } ::= { alarmActiveStatsTable 1 } AlarmActiveStatsEntry ::= SEQUENCE { alarmActiveStatsActiveCurrent Gauge32, alarmActiveStatsActives ZeroBasedCounter32, alarmActiveStatsLastRaise TimeTicks, alarmActiveStatsLastClear TimeTicks } alarmActiveStatsActiveCurrent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of currently active alarms on the system." ::= { alarmActiveStatsEntry 1 } alarmActiveStatsActives OBJECT-TYPE SYNTAX ZeroBasedCounter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of active alarms since system restarted." ::= { alarmActiveStatsEntry 2 } alarmActiveStatsLastRaise OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time of the last alarm raise for this alarm list. If no alarm raises have occurred since the last re-initialization of the local network management subsystem, then this object contains a zero value." ::= { alarmActiveStatsEntry 3 } alarmActiveStatsLastClear OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time of the last alarm clear for this alarm list. If no alarm clears have occurred since the last re-initialization of the local network management subsystem, then this object contains a zero value." ::= { alarmActiveStatsEntry 4 } -- Alarm Clear alarmClearMaximum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of cleared alarms to store in the alarmClearTable. When this number is reached, the cleared alarms with the earliest clear time will be removed from the table." ::= { alarmClear 1 } alarmClearTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmClearEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information on cleared alarms." ::= { alarmClear 2 } alarmClearEntry OBJECT-TYPE SYNTAX AlarmClearEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information on a cleared alarm." INDEX { alarmListName, alarmClearDateAndTime, alarmClearIndex } ::= { alarmClearTable 1 } AlarmClearEntry ::= SEQUENCE { alarmClearIndex Unsigned32, alarmClearDateAndTime DateAndTime, alarmClearEngineID LocalSnmpEngineOrZeroLenStr, alarmClearEngineAddressType InetAddressType, alarmClearEngineAddress InetAddress, alarmClearContextName SnmpAdminString, alarmClearNotificationID OBJECT IDENTIFIER, alarmClearResourceId ResourceId, alarmClearLogIndex Unsigned32, alarmClearModelPointer RowPointer } alarmClearIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An integer which acts as the index of entries within the named alarm list. It wraps back to 1 after it reaches its maximum value. This object has the same value as the alarmActiveIndex that this alarm instance had when it was active." ::= { alarmClearEntry 1 } alarmClearDateAndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS not-accessible STATUS current DESCRIPTION "The local date and time when the alarm cleared. This object facilitates retrieving all instances of alarms that have been cleared since a given point in time. Implementations MUST include the offset from UTC, if available. Implementation in environments in which the UTC offset is not available is NOT RECOMMENDED." ::= { alarmClearEntry 2 } alarmClearEngineID OBJECT-TYPE SYNTAX LocalSnmpEngineOrZeroLenStr MAX-ACCESS read-only STATUS current DESCRIPTION "The identification of the SNMP engine at which the alarm originated. If the alarm is from an SNMPv1 system this object is a zero length string." ::= { alarmClearEntry 3 } alarmClearEngineAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates what type of address is stored in the alarmActiveEngineAddress object - IPv4, IPv6, DNS, etc." ::= { alarmClearEntry 4 } alarmClearEngineAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The Address of the SNMP engine on which the alarm was occurring. This is used to identify the source of an SNMPv1 trap, since an alarmActiveEngineId cannot be extracted from the SNMPv1 trap PDU. This object MUST always be instantiated, even if the list can contain alarms from only one engine." ::= { alarmClearEntry 5 } alarmClearContextName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the SNMP MIB context from which the alarm came. For SNMPv1 traps this is the community string from the Trap. Note that care needs to be taken when selecting community strings to ensure that these can be represented as a well-formed SnmpAdminString. Community or Context names that are not well-formed SnmpAdminStrings will be mapped to zero length strings. If the alarm's source SNMP engine is known not to support multiple contexts, this object is a zero length string." ::= { alarmClearEntry 6 } alarmClearNotificationID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The NOTIFICATION-TYPE object identifier of the alarm clear." ::= { alarmClearEntry 7 } alarmClearResourceId OBJECT-TYPE SYNTAX ResourceId MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the resource that was under alarm. If there is no corresponding resource, then the value of this object MUST be 0.0." ::= { alarmClearEntry 8 } alarmClearLogIndex OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This number MUST be the same as the log index of the applicable row in the notification log MIB, if it exists. If no log index applies to the trap, then this object MUST have the value of 0." ::= { alarmClearEntry 9 } alarmClearModelPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "A pointer to the corresponding row in the alarmModelTable for this cleared alarm." ::= { alarmClearEntry 10 } -- Notifications alarmActiveState NOTIFICATION-TYPE OBJECTS { alarmActiveModelPointer, alarmActiveResourceId } STATUS current DESCRIPTION "An instance of the alarm indicated by alarmActiveModelPointer has been raised against the entity indicated by alarmActiveResourceId. The agent must throttle the generation of consecutive alarmActiveState traps so that there is at least a two-second gap between traps of this type against the same alarmActiveModelPointer and alarmActiveResourceId. When traps are throttled, they are dropped, not queued for sending at a future time. A management application should periodically check the value of alarmActiveLastChanged to detect any missed alarmActiveState notification-events, e.g., due to throttling or transmission loss." ::= { alarmNotifications 2 } alarmClearState NOTIFICATION-TYPE OBJECTS { alarmActiveModelPointer, alarmActiveResourceId } STATUS current DESCRIPTION "An instance of the alarm indicated by alarmActiveModelPointer has been cleared against the entity indicated by alarmActiveResourceId. The agent must throttle the generation of consecutive alarmActiveClear traps so that there is at least a two-second gap between traps of this type against the same alarmActiveModelPointer and alarmActiveResourceId. When traps are throttled, they are dropped, not queued for sending at a future time. A management application should periodically check the value of alarmActiveLastChanged to detect any missed alarmClearState notification-events, e.g., due to throttling or transmission loss." ::= { alarmNotifications 3 } -- Conformance alarmConformance OBJECT IDENTIFIER ::= { alarmMIB 2 } alarmCompliances OBJECT IDENTIFIER ::= { alarmConformance 1 } alarmCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for systems supporting the Alarm MIB." MODULE -- this module MANDATORY-GROUPS { alarmActiveGroup, alarmModelGroup } GROUP alarmActiveStatsGroup DESCRIPTION "This group is optional." GROUP alarmClearGroup DESCRIPTION "This group is optional." GROUP alarmNotificationsGroup DESCRIPTION "This group is optional." ::= { alarmCompliances 1 } alarmGroups OBJECT IDENTIFIER ::= { alarmConformance 2 } alarmModelGroup OBJECT-GROUP OBJECTS { alarmModelLastChanged, alarmModelNotificationId, alarmModelVarbindIndex, alarmModelVarbindValue, alarmModelDescription, alarmModelSpecificPointer, alarmModelVarbindSubtree, alarmModelResourcePrefix, alarmModelRowStatus } STATUS current DESCRIPTION "Alarm model group." ::= { alarmGroups 1} alarmActiveGroup OBJECT-GROUP OBJECTS { alarmActiveLastChanged, alarmActiveOverflow, alarmActiveEngineID, alarmActiveEngineAddressType, alarmActiveEngineAddress, alarmActiveContextName, alarmActiveVariables, alarmActiveNotificationID, alarmActiveResourceId, alarmActiveDescription, alarmActiveLogPointer, alarmActiveModelPointer, alarmActiveSpecificPointer, alarmActiveVariableID, alarmActiveVariableValueType, alarmActiveVariableCounter32Val, alarmActiveVariableUnsigned32Val, alarmActiveVariableTimeTicksVal, alarmActiveVariableInteger32Val, alarmActiveVariableOctetStringVal, alarmActiveVariableIpAddressVal, alarmActiveVariableOidVal, alarmActiveVariableCounter64Val, alarmActiveVariableOpaqueVal } STATUS current DESCRIPTION "Active Alarm list group." ::= { alarmGroups 2} alarmActiveStatsGroup OBJECT-GROUP OBJECTS { alarmActiveStatsActives, alarmActiveStatsActiveCurrent, alarmActiveStatsLastRaise, alarmActiveStatsLastClear } STATUS current DESCRIPTION "Active alarm summary group." ::= { alarmGroups 3} alarmClearGroup OBJECT-GROUP OBJECTS { alarmClearMaximum, alarmClearEngineID, alarmClearEngineAddressType, alarmClearEngineAddress, alarmClearContextName, alarmClearNotificationID, alarmClearResourceId, alarmClearLogIndex, alarmClearModelPointer } STATUS current DESCRIPTION "Cleared alarm group." ::= { alarmGroups 4} alarmNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { alarmActiveState, alarmClearState } STATUS current DESCRIPTION "The collection of notifications that can be used to model alarms for faults lacking pre-existing notification definitions." ::= { alarmGroups 6 } END