Server : Apache System : Linux server1.cgrithy.com 3.10.0-1160.95.1.el7.x86_64 #1 SMP Mon Jul 24 13:59:37 UTC 2023 x86_64 User : nobody ( 99) PHP Version : 8.1.23 Disable Function : NONE Directory : /usr/share/mibs/ietf/ |
RFC1382-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, Gauge, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString, transmission FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 EntryStatus FROM RFC1271-MIB PositiveInteger, IfIndexType FROM RFC1381-MIB; x25 OBJECT IDENTIFIER ::= { transmission 5 } -- Support of the X25 subtree and all subtrees under it -- is mandatory for all agents of system that implement X.25. X121Address ::= OCTET STRING (SIZE(0..17)) -- 0 to 17 bytes in length containing the ASCII -- characters [0-9], each octet contains one digit -- of the address. -- ########################################################### -- X.25 Administration Table -- ########################################################### x25AdmnTable OBJECT-TYPE SYNTAX SEQUENCE OF X25AdmnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the administratively set configuration parameters for an X.25 Packet Level Entity (PLE). Most of the objects in this table have corresponding objects in the x25OperTable. This table contains the values as last set by the administrator. The x25OperTable contains the values actually in use by an X.25 PLE. Changing an administrative value may or may not change a current operating value. The operating value may not change until the interface is restarted. Some implementations may change the values immediately upon changing the administrative table. All implementations are required to load the values from the administrative table when initializing a PLE." ::= { x25 1 } x25AdmnEntry OBJECT-TYPE SYNTAX X25AdmnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries of x25AdmnTable." INDEX { x25AdmnIndex } ::= { x25AdmnTable 1 } X25AdmnEntry ::= SEQUENCE { x25AdmnIndex IfIndexType, x25AdmnInterfaceMode INTEGER, x25AdmnMaxActiveCircuits INTEGER, x25AdmnPacketSequencing INTEGER, x25AdmnRestartTimer PositiveInteger, x25AdmnCallTimer PositiveInteger, x25AdmnResetTimer PositiveInteger, x25AdmnClearTimer PositiveInteger, x25AdmnWindowTimer PositiveInteger, x25AdmnDataRxmtTimer PositiveInteger, x25AdmnInterruptTimer PositiveInteger, x25AdmnRejectTimer PositiveInteger, x25AdmnRegistrationRequestTimer PositiveInteger, x25AdmnMinimumRecallTimer PositiveInteger, x25AdmnRestartCount INTEGER, x25AdmnResetCount INTEGER, x25AdmnClearCount INTEGER, x25AdmnDataRxmtCount INTEGER, x25AdmnRejectCount INTEGER, x25AdmnRegistrationRequestCount INTEGER, x25AdmnNumberPVCs INTEGER, x25AdmnDefCallParamId OBJECT IDENTIFIER, x25AdmnLocalAddress X121Address, x25AdmnProtocolVersionSupported OBJECT IDENTIFIER } x25AdmnIndex OBJECT-TYPE SYNTAX IfIndexType ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value for the X.25 Interface." ::= { x25AdmnEntry 1 } x25AdmnInterfaceMode OBJECT-TYPE SYNTAX INTEGER { dte (1), dce (2), dxe (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the mode will be determined by XID negotiation." REFERENCE "10733 5.9 interfaceMode" ::= { x25AdmnEntry 2 } x25AdmnMaxActiveCircuits OBJECT-TYPE SYNTAX INTEGER (0..4096) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of circuits this PLE can support; including PVCs." REFERENCE "10733 5.9 maxActiveCircuits; See ISO 8208, Section 3.7" ::= { x25AdmnEntry 3 } x25AdmnPacketSequencing OBJECT-TYPE SYNTAX INTEGER { modulo8 (1), modulo128 (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The modulus of the packet sequence number space." REFERENCE "10733 extendedPacketSequencing; See ISO 8208 Section 7.1.1" ::= { x25AdmnEntry 4 } x25AdmnRestartTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "The T20 restart timer in milliseconds." REFERENCE "10733 5.9 restartTime See ISO 8208 Section 4.1, table 26" ::= { x25AdmnEntry 5 } x25AdmnCallTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "The T21 Call timer in milliseconds." REFERENCE "10733 callTime; See ISO 8208 Section 5.2.1, table 26" ::= { x25AdmnEntry 6 } x25AdmnResetTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "The T22 Reset timer in milliseconds." REFERENCE "10733 resetTime; See ISO 8208 Section 8.1, table 26" ::= { x25AdmnEntry 7 } x25AdmnClearTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "The T23 Clear timer in milliseconds." REFERENCE "10733 clearTime; See ISO 8208 Section 5.5.1, table 26" ::= { x25AdmnEntry 8 } x25AdmnWindowTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "The T24 window status transmission timer in milliseconds. A value of 2147483647 indicates no window timer in use." REFERENCE "10733 5.10.1 windowTime (opt); See ISO 8208 Section 11.2.2, table 26" ::= { x25AdmnEntry 9 } x25AdmnDataRxmtTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "The T25 data retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use." REFERENCE "10733 5.10.1 dataRetransmissionTime (opt); See ISO 8208 Section 11.2.1, table 26" ::= { x25AdmnEntry 10 } x25AdmnInterruptTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "The T26 interrupt timer in milliseconds. A value of 2147483647 indicates no interrupt timer in use." REFERENCE "10733 interruptTime; See ISO 8208 Section 6.8.1, table 26" ::= { x25AdmnEntry 11 } x25AdmnRejectTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use." REFERENCE "10733 5.10.1 dataRejectTime (opt); See ISO 8208 Section 13.4.1, table 26" ::= { x25AdmnEntry 12 } x25AdmnRegistrationRequestTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use." REFERENCE "10733 5.8.1 registrationRequestTime (opt) See ISO 8208 Section 13.1.1.1, table 26" ::= { x25AdmnEntry 13 } x25AdmnMinimumRecallTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "Minimum time interval between unsuccessful call attempts in milliseconds." REFERENCE "10733 5.9 minimum RecallTimer" ::= { x25AdmnEntry 14 } x25AdmnRestartCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The R20 restart retransmission count." REFERENCE "10733 5.9 restartCount; See ISO 8208 Section 4.1, table 27" ::= { x25AdmnEntry 15 } x25AdmnResetCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The r22 Reset retransmission count." REFERENCE "10733 resetCount; See section ISO 8208 8.1, table 27" ::= { x25AdmnEntry 16 } x25AdmnClearCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The r23 Clear retransmission count." REFERENCE "10733 clearCount; See ISO 8208 Section 5.5.1, table 27" ::= { x25AdmnEntry 17 } x25AdmnDataRxmtCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use." REFERENCE "10733 5.10.1 dataRetransmissionCount (opt) See ISO 8208 Section 11.2.1, table 27" ::= { x25AdmnEntry 18 } x25AdmnRejectCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use." REFERENCE "10733 5.10.1 dataRejectCount (opt)" ::= { x25AdmnEntry 19 } x25AdmnRegistrationRequestCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use." REFERENCE "10733 5.8.1 registrationRequestCount (opt); See ISO 8208 Section 13.1.1.1, table 27" ::= { x25AdmnEntry 20 } x25AdmnNumberPVCs OBJECT-TYPE SYNTAX INTEGER (0..4096) ACCESS read-write STATUS mandatory DESCRIPTION "The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number." ::= { x25AdmnEntry 21 } x25AdmnDefCallParamId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE." ::= { x25AdmnEntry 22 } x25AdmnLocalAddress OBJECT-TYPE SYNTAX X121Address ACCESS read-write STATUS mandatory DESCRIPTION "The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs." REFERENCE "10733 5.9 localDTEAddress" ::= { x25AdmnEntry 23 } x25AdmnProtocolVersionSupported OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "Identifies the version of the X.25 protocol this interface should support. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree." REFERENCE "10733 5.9 protocolVersionSupported" ::= { x25AdmnEntry 24 } -- ########################################################### -- X.25 Operational Table -- ########################################################### x25OperTable OBJECT-TYPE SYNTAX SEQUENCE OF X25OperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The operation parameters in use by the X.25 PLE." ::= { x25 2 } x25OperEntry OBJECT-TYPE SYNTAX X25OperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries of x25OperTable." INDEX { x25OperIndex } ::= { x25OperTable 1 } X25OperEntry ::= SEQUENCE { x25OperIndex IfIndexType, x25OperInterfaceMode INTEGER, x25OperMaxActiveCircuits INTEGER, x25OperPacketSequencing INTEGER, x25OperRestartTimer PositiveInteger, x25OperCallTimer PositiveInteger, x25OperResetTimer PositiveInteger, x25OperClearTimer PositiveInteger, x25OperWindowTimer PositiveInteger, x25OperDataRxmtTimer PositiveInteger, x25OperInterruptTimer PositiveInteger, x25OperRejectTimer PositiveInteger, x25OperRegistrationRequestTimer PositiveInteger, x25OperMinimumRecallTimer PositiveInteger, x25OperRestartCount INTEGER, x25OperResetCount INTEGER, x25OperClearCount INTEGER, x25OperDataRxmtCount INTEGER, x25OperRejectCount INTEGER, x25OperRegistrationRequestCount INTEGER, x25OperNumberPVCs INTEGER, x25OperDefCallParamId OBJECT IDENTIFIER, x25OperLocalAddress X121Address, x25OperDataLinkId OBJECT IDENTIFIER, x25OperProtocolVersionSupported OBJECT IDENTIFIER } x25OperIndex OBJECT-TYPE SYNTAX IfIndexType ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value for the X.25 interface." ::= { x25OperEntry 1 } x25OperInterfaceMode OBJECT-TYPE SYNTAX INTEGER { dte (1), dce (2), dxe (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the role will be determined by XID negotiation at the Link Layer and that negotiation has not yet taken place." REFERENCE "10733 5.9 interfaceMode" ::= { x25OperEntry 2 } x25OperMaxActiveCircuits OBJECT-TYPE SYNTAX INTEGER (0..4096) ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of circuits this PLE can support." REFERENCE "10733 5.9 maxActiveCircuits See ISO 8208, Section 3.7" ::= { x25OperEntry 3 } x25OperPacketSequencing OBJECT-TYPE SYNTAX INTEGER { modulo8 (1), modulo128 (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The modulus of the packet sequence number space." REFERENCE "10733 extendedPacketSequencing; See ISO 8208 Section 7.1.1" ::= { x25OperEntry 4 } x25OperRestartTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T20 restart timer in milliseconds." REFERENCE "10733 5.9 restartTime; See ISO 8208 Section 4.1, table 26" ::= { x25OperEntry 5 } x25OperCallTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T21 Call timer in milliseconds." REFERENCE "10733 callTime; See ISO 8208 Section 5.2.1, table 26" ::= { x25OperEntry 6 } x25OperResetTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T22 Reset timer in milliseconds." REFERENCE "10733 resetTime; See ISO 8208 Section 8.1, table 26" ::= { x25OperEntry 7 } x25OperClearTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T23 Clear timer in milliseconds." REFERENCE "10733 clearTime; See ISO 8208 Section 5.5.1, table 26" ::= { x25OperEntry 8 } x25OperWindowTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T24 window status transmission timer milliseconds. A value of 2147483647 indicates no window timer in use." REFERENCE "10733 5.10.1 windowTime (opt); See ISO 8208 Section 11.2.2, table 26" ::= { x25OperEntry 9 } x25OperDataRxmtTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T25 Data Retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use." REFERENCE "10733 5.10.1 dataRetransmissionTime (opt); See ISO 8208 Section 11.2.1, table 26" ::= { x25OperEntry 10 } x25OperInterruptTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T26 Interrupt timer in milliseconds. A value of 2147483647 indicates interrupts are not being used." REFERENCE "10733 interruptTime; See ISO 8208 Section 6.8.1, table 26" ::= { x25OperEntry 11 } x25OperRejectTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use." REFERENCE "10733 5.10.1 dataRejectTime (opt); See ISO 8208 Section 13.4.1, table 26" ::= { x25OperEntry 12 } x25OperRegistrationRequestTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use." REFERENCE "10733 5.8.1 registrationRequestTime (opt); See ISO 8208 Section 13.1.1.1, table 26" ::= { x25OperEntry 13 } x25OperMinimumRecallTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "Minimum time interval between unsuccessful call attempts in milliseconds." REFERENCE "10733 5.9 minimum RecallTimer" ::= { x25OperEntry 14 } x25OperRestartCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The R20 restart retransmission count." REFERENCE "10733 5.9 restartCount See ISO 8208 Section 4.1, table 27" ::= { x25OperEntry 15 } x25OperResetCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The r22 Reset retransmission count." REFERENCE "10733 resetCount; See section ISO 8208 8.1, table 27" ::= { x25OperEntry 16 } x25OperClearCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The r23 Clear retransmission count." REFERENCE "10733 clearCount; See ISO 8208 Section 5.5.1, table 27" ::= { x25OperEntry 17 } x25OperDataRxmtCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The R25 Data retransmission count. This value is undefined if the x25OperDataRxmtTimer indicates no timer in use." REFERENCE "10733 5.10.1 dataRetransmissionCount (opt); See ISO 8208 Section 11.2.1, table 27" ::= { x25OperEntry 18 } x25OperRejectCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The R27 reject retransmission count. This value is undefined if the x25OperRejectTimer indicates no timer in use." REFERENCE "10733 5.10.1 dataRejectCount (opt)" ::= { x25OperEntry 19 } x25OperRegistrationRequestCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The R28 Registration retransmission Count. This value is undefined if the x25OperREgistrationRequestTimer indicates no timer in use." REFERENCE "10733 5.8.1 registrationRequestCount (opt); See ISO 8208 Section 13.1.1.1, table 27" ::= { x25OperEntry 20 } x25OperNumberPVCs OBJECT-TYPE SYNTAX INTEGER (0..4096) ACCESS read-only STATUS mandatory DESCRIPTION "The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number." ::= { x25OperEntry 21 } x25OperDefCallParamId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable that contains the default call parameters for this PLE." ::= { x25OperEntry 22 } x25OperLocalAddress OBJECT-TYPE SYNTAX X121Address ACCESS read-only STATUS mandatory DESCRIPTION "The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs." REFERENCE "10733 5.9 localDTEAddress" ::= { x25OperEntry 23 } x25OperDataLinkId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This identifies the instance of the index object in the first table of the most device specific MIB for the interface used by this PLE." ::= { x25OperEntry 24 } x25OperProtocolVersionSupported OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the version of the X.25 protocol this interface supports. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree." REFERENCE "10733 5.9 protocolVersionSupported" ::= { x25OperEntry 25 } -- MIB-II also provides: -- ifDescr: -- On an X.25 interface this must include sufficient -- information to enable the system's administrator -- to determine the appropriate configuration -- information on a system having multiple X.25 -- subnetworks. -- ifType: ddn-x25 or rfc877-x25 -- an interface of type ddn-x25 will use an algorithm to -- translate between X.121 address and IP addresses. -- An interface of type rfc877-x25 will use a -- configuration table to translate between X.121 -- addresses and IP addresses. -- ifMtu: the maximum PDU a higher layer can pass to X.25 or -- receive from X.25 -- ifSpeed: -- This will be the value of the local clock for this line. -- A value of zero indicates external clocking. -- ifAdminStatus: -- ifOperStatus -- ifLastChange -- ########################################################### -- X.25 Statistics Table -- ########################################################### x25StatTable OBJECT-TYPE SYNTAX SEQUENCE OF X25StatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Statistics information about this X.25 PLE." ::= { x25 3 } x25StatEntry OBJECT-TYPE SYNTAX X25StatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries of the x25StatTable." INDEX { x25StatIndex } ::= { x25StatTable 1 } X25StatEntry ::= SEQUENCE { x25StatIndex IfIndexType, x25StatInCalls Counter, x25StatInCallRefusals Counter, x25StatInProviderInitiatedClears Counter, x25StatInRemotelyInitiatedResets Counter, x25StatInProviderInitiatedResets Counter, x25StatInRestarts Counter, x25StatInDataPackets Counter, x25StatInAccusedOfProtocolErrors Counter, x25StatInInterrupts Counter, x25StatOutCallAttempts Counter, x25StatOutCallFailures Counter, x25StatOutInterrupts Counter, x25StatOutDataPackets Counter, x25StatOutgoingCircuits Gauge, x25StatIncomingCircuits Gauge, x25StatTwowayCircuits Gauge, x25StatRestartTimeouts Counter, x25StatCallTimeouts Counter, x25StatResetTimeouts Counter, x25StatClearTimeouts Counter, x25StatDataRxmtTimeouts Counter, x25StatInterruptTimeouts Counter, x25StatRetryCountExceededs Counter, x25StatClearCountExceededs Counter } x25StatIndex OBJECT-TYPE SYNTAX IfIndexType ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value for the X.25 interface." ::= { x25StatEntry 1 } x25StatInCalls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of incoming calls received." ::= { x25StatEntry 2 } x25StatInCallRefusals OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast select." ::= { x25StatEntry 3 } x25StatInProviderInitiatedClears OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of clear requests with a cause code other than DTE initiated." REFERENCE "10733 providerInitiatedDisconnect" ::= { x25StatEntry 4 } x25StatInRemotelyInitiatedResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of reset requests received with cause code DTE initiated." REFERENCE "10733 remotelyInitiatedResets" ::= { x25StatEntry 5 } x25StatInProviderInitiatedResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of reset requests received with cause code other than DTE initiated." REFERENCE "10733 ProviderInitiatedResets" ::= { x25StatEntry 6 } x25StatInRestarts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE interface. This only counts restarts received when the PLE already has an established connection with the remove PLE." REFERENCE "10733 5.9 remotelyInitiatedRestarts" ::= { x25StatEntry 7 } x25StatInDataPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of data packets received." REFERENCE "10733 5.9 dataPacketsReceived." ::= { x25StatEntry 8 } x25StatInAccusedOfProtocolErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets." REFERENCE "CD 10733 5.9 accusedOfProtocolError" ::= { x25StatEntry 9 } x25StatInInterrupts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of interrupt packets received by the PLE or over the PVC/VC." REFERENCE "10733 interruptPacketsReceived" ::= { x25StatEntry 10 } x25StatOutCallAttempts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of calls attempted." REFERENCE "10733 5.9 callAttempts" ::= { x25StatEntry 11 } x25StatOutCallFailures OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of call attempts which failed. This includes calls that were cleared because of restrictive fast select." ::= { x25StatEntry 12 } x25StatOutInterrupts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of interrupt packets send by the PLE or over the PVC/VC." REFERENCE "10733 InterruptPacketsSent" ::= { x25StatEntry 13 } x25StatOutDataPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of data packets sent by this PLE." REFERENCE "10733 dataPacketSent" ::= { x25StatEntry 14 } x25StatOutgoingCircuits OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of active outgoing circuits. This includes call requests sent but not yet confirmed. This does not count PVCs." ::= { x25StatEntry 15 } x25StatIncomingCircuits OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of active Incoming Circuits. This includes call indications received but not yet acknowledged. This does not count PVCs." ::= { x25StatEntry 16 } x25StatTwowayCircuits OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of active two-way Circuits. This includes call requests sent but not yet confirmed. This does not count PVCs." ::= { x25StatEntry 17 } x25StatRestartTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T20 restart timer expired." REFERENCE "10733 5.9 restartTimeouts" ::= { x25StatEntry 18 } x25StatCallTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T21 call timer expired." REFERENCE "10733 5.9 callTimeouts" ::= { x25StatEntry 19 } x25StatResetTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T22 reset timer expired." REFERENCE "10733 5.9 resetTimeouts" ::= { x25StatEntry 20 } x25StatClearTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T23 clear timer expired." REFERENCE "10733 5.9 clearTimeouts" ::= { x25StatEntry 21 } x25StatDataRxmtTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T25 data timer expired." REFERENCE "10733 5.9 dataRetransmissionsTimerExpiries" ::= { x25StatEntry 22 } x25StatInterruptTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T26 interrupt timer expired." REFERENCE "10733 5.9 interruptTimerExpires" ::= { x25StatEntry 23 } x25StatRetryCountExceededs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times a retry counter was exhausted." REFERENCE "10733 5.9 retryCountsExceeded" ::= { x25StatEntry 24 } x25StatClearCountExceededs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the R23 clear count was exceeded." REFERENCE "10733 5.9 clearCountsExceeded" ::= { x25StatEntry 25 } -- MIB-II also contains: -- ifInOctets: Number of data octets delivered to upper -- layer entities. -- ifInUcastPkts: Number of packets with a clear M-bit -- delivered to higher layer entities. -- ifDiscards: Number of packets dropped for lack of buffering -- ifInErrors: Number of packets received containing errors -- REFERENCE ProtocolErrorsDetectedLocally -- ifInUnknownProtos: Number of packets with unknown circuit -- identifier. -- ifOutOctets: Number of data octets delivered by -- X.25 to upper layers. -- ifOutUcastPkts: Number of packets with a clear M-bit -- received from higher layer entities. -- ########################################################### -- X.25 Channel Table -- ########################################################### x25ChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF X25ChannelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "These objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interfaces has started may not be reflected in the operating PLE." REFERENCE "See ISO 8208, Section 3.7" ::= { x25 4 } x25ChannelEntry OBJECT-TYPE SYNTAX X25ChannelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries of x25ChannelTable." REFERENCE "This provides the information available in 10733 logicalChannelAssignments." INDEX { x25ChannelIndex } ::= { x25ChannelTable 1 } X25ChannelEntry ::= SEQUENCE { x25ChannelIndex IfIndexType, x25ChannelLIC INTEGER, x25ChannelHIC INTEGER, x25ChannelLTC INTEGER, x25ChannelHTC INTEGER, x25ChannelLOC INTEGER, x25ChannelHOC INTEGER } x25ChannelIndex OBJECT-TYPE SYNTAX IfIndexType ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value for the X.25 Interface." ::= { x25ChannelEntry 1 } x25ChannelLIC OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "Lowest Incoming channel." ::= { x25ChannelEntry 2 } x25ChannelHIC OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "Highest Incoming channel. A value of zero indicates no channels in this range." ::= { x25ChannelEntry 3 } x25ChannelLTC OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "Lowest Two-way channel." ::= { x25ChannelEntry 4 } x25ChannelHTC OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "Highest Two-way channel. A value of zero indicates no channels in this range." ::= { x25ChannelEntry 5 } x25ChannelLOC OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "Lowest outgoing channel." ::= { x25ChannelEntry 6 } x25ChannelHOC OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "Highest outgoing channel. A value of zero indicates no channels in this range." ::= { x25ChannelEntry 7 } -- ########################################################### -- X25 Per Circuits Information Table -- ########################################################### x25CircuitTable OBJECT-TYPE SYNTAX SEQUENCE OF X25CircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "These objects contain general information about a specific circuit of an X.25 PLE." ::= { x25 5 } x25CircuitEntry OBJECT-TYPE SYNTAX X25CircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries of x25CircuitTable." INDEX { x25CircuitIndex, x25CircuitChannel } ::= { x25CircuitTable 1 } X25CircuitEntry ::= SEQUENCE { x25CircuitIndex IfIndexType, x25CircuitChannel INTEGER, x25CircuitStatus INTEGER, x25CircuitEstablishTime TimeTicks, x25CircuitDirection INTEGER, x25CircuitInOctets Counter, x25CircuitInPdus Counter, x25CircuitInRemotelyInitiatedResets Counter, x25CircuitInProviderInitiatedResets Counter, x25CircuitInInterrupts Counter, x25CircuitOutOctets Counter, x25CircuitOutPdus Counter, x25CircuitOutInterrupts Counter, x25CircuitDataRetransmissionTimeouts Counter, x25CircuitResetTimeouts Counter, x25CircuitInterruptTimeouts Counter, x25CircuitCallParamId OBJECT IDENTIFIER, x25CircuitCalledDteAddress X121Address, x25CircuitCallingDteAddress X121Address, x25CircuitOriginallyCalledAddress X121Address, x25CircuitDescr DisplayString } x25CircuitIndex OBJECT-TYPE SYNTAX IfIndexType ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value for the X.25 Interface." ::= { x25CircuitEntry 1 } x25CircuitChannel OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The channel number for this circuit." ::= { x25CircuitEntry 2 } x25CircuitStatus OBJECT-TYPE SYNTAX INTEGER { -- state table states invalid (1), closed (2), -- (p1) calling (3), -- (p2,p3,p5) open (4), -- (p4) clearing (5), -- (p6,p7) pvc (6), pvcResetting (7), startClear (8), -- Close cmd startPvcResetting (9), -- Reset cmd other (10) } ACCESS read-write STATUS mandatory DESCRIPTION "This object reports the current status of the circuit. An existing instance of this object can only be set to startClear, startPvcResetting, or invalid. An instance with the value calling or open can only be set to startClear and that action will start clearing the circuit. An instance with the value PVC can only be set to startPvcResetting or invalid and that action resets the PVC or deletes the circuit respectively. The values startClear or startPvcResetting will never be returned by an agent. An attempt to set the status of an existing instance to a value other than one of these values will result in an error. A non-existing instance can be set to PVC to create a PVC if the implementation supports dynamic creation of PVCs. Some implementations may only allow creation and deletion of PVCs if the interface is down. Since the instance identifier will supply the PLE index and the channel number, setting this object alone supplies sufficient information to create the instance. All the DEFVAL clauses for the other objects of this table are appropriate for creating a PVC; PLEs creating entries for placed or accepted calls will use values appropriate for the call rather than the value of the DEFVAL clause. Two managers trying to create the same PVC can determine from the return code which manager succeeded and which failed (the failing manager fails because it can not set a value of PVC for an existing object). An entry in the closed or invalid state may be deleted or reused at the agent's convence. If the entry is kept in the closed state, the values of the parameters associated with the entry must be correct. Closed implies the values in the circuit table are correct. The value of invalid indicates the other values in the table are invalid. Many agents may never return a value of invalid because they dynamically allocate and free unused table entries. An agent for a statically configured systems can return invalid to indicate the entry has not yet been used so the counters contain no information." REFERENCE "See ISO 8208, table 33 for (p<n>) state table" ::= { x25CircuitEntry 3 } x25CircuitEstablishTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs, this is the time the call indication was received. For PVCs this is the time the PVC was able to pass data to a higher layer entity without loss of data." ::= { x25CircuitEntry 4 } x25CircuitDirection OBJECT-TYPE SYNTAX INTEGER { incoming (1), outgoing (2), pvc (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The direction of the call that established this circuit." REFERENCE "10733 direction" DEFVAL { pvc } ::= { x25CircuitEntry 5 } -- X25 Circuit data flow statistics x25CircuitInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets of user data delivered to upper layer." REFERENCE "5.11 octetsReceivedCounter" ::= { x25CircuitEntry 6 } x25CircuitInPdus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PDUs received for this circuit." REFERENCE "10733 5.11 dataPacketsReceived" ::= { x25CircuitEntry 7 } x25CircuitInRemotelyInitiatedResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Resets received for this circuit with cause code of DTE initiated." REFERENCE "10733 remotelyInitiatedResets" ::= { x25CircuitEntry 8 } x25CircuitInProviderInitiatedResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Resets received for this circuit with cause code other than DTE initiated." REFERENCE "10733 ProviderInitiatedResets" ::= { x25CircuitEntry 9 } x25CircuitInInterrupts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of interrupt packets received for this circuit." REFERENCE "10733 interruptPacketsReceived" ::= { x25CircuitEntry 10 } x25CircuitOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets of user data sent for this circuit." REFERENCE "10733 5.11 octetsSentCounter" ::= { x25CircuitEntry 11 } x25CircuitOutPdus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PDUs sent for this circuit." REFERENCE "10733 5.11 dataPacketsSent" ::= { x25CircuitEntry 12 } x25CircuitOutInterrupts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of interrupt packets sent on this circuit." REFERENCE "10733 interruptPacketsSent" ::= { x25CircuitEntry 13 } -- X25 circuit timer statistics x25CircuitDataRetransmissionTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T25 data retransmission timer expired for this circuit." REFERENCE "10733 5.11 dataRetransmissionTimerExpiries" ::= { x25CircuitEntry 14 } x25CircuitResetTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T22 reset timer expired for this circuit." REFERENCE "10733 5.11 resetTimeouts" ::= { x25CircuitEntry 15 } x25CircuitInterruptTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T26 Interrupt timer expired for this circuit." REFERENCE "10733 interruptTimerExpiries" ::= { x25CircuitEntry 16 } x25CircuitCallParamId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The entry referenced must contain the values that are currently in use by the circuit rather than proposed values. A value of NULL indicates the circuit is a PVC or is using all the default parameters." DEFVAL { {0 0} } ::= { x25CircuitEntry 17 } x25CircuitCalledDteAddress OBJECT-TYPE SYNTAX X121Address ACCESS read-write STATUS mandatory DESCRIPTION "For incoming calls, this is the called address from the call indication packet. For outgoing calls, this is the called address from the call confirmation packet. This will be zero length for PVCs." REFERENCE "10733 calledDTEAddress" DEFVAL { ''h } ::= { x25CircuitEntry 18 } x25CircuitCallingDteAddress OBJECT-TYPE SYNTAX X121Address ACCESS read-write STATUS mandatory DESCRIPTION "For incoming calls, this is the calling address from the call indication packet. For outgoing calls, this is the calling address from the call confirmation packet. This will be zero length for PVCs." REFERENCE "10733 callingDTEAddress" DEFVAL { ''h } ::= { x25CircuitEntry 19 } x25CircuitOriginallyCalledAddress OBJECT-TYPE SYNTAX X121Address ACCESS read-write STATUS mandatory DESCRIPTION "For incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it will be called address from the call indication packet. For outgoing calls, this is the address from the call request packet. This will be zero length for PVCs." REFERENCE "10733 originallyCalledAddress" DEFVAL { ''h } ::= { x25CircuitEntry 20 } x25CircuitDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "A descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of the circuit. The agent may return the process identifier and user name for the process using the circuit. Alternative the agent may return the name of the configuration entry that caused a bridge to establish the circuit. A zero length value indicates the agent doesn't have any additional information." DEFVAL { ''h } ::= { x25CircuitEntry 21 } -- ########################################################### -- The Cleared Circuit Table -- ########################################################### x25ClearedCircuitEntriesRequested OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTION "The requested number of entries for the agent to keep in the x25ClearedCircuit table." ::= { x25 6 } x25ClearedCircuitEntriesGranted OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The actual number of entries the agent will keep in the x25ClearedCircuit Table." ::= { x25 7 } x25ClearedCircuitTable OBJECT-TYPE SYNTAX SEQUENCE OF X25ClearedCircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of entries about closed circuits. Entries must be made in this table whenever circuits are closed and the close request or close indication packet contains a clearing cause other than DTE Originated or a Diagnostic code field other than Higher Layer Initiated disconnection-normal. An agent may optionally make entries for normal closes (to record closing facilities or other information). Agents will delete the oldest entry in the table when adding a new entry would exceed agent resources. Agents are required to keep the last entry put in the table and may keep more entries. The object x25OperClearEntriesGranted returns the maximum number of entries kept in the table." REFERENCE "See ISO 8208 Section 12.2.3.1.1 and 12.2.3.1.2" ::= { x25 8 } x25ClearedCircuitEntry OBJECT-TYPE SYNTAX X25ClearedCircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a cleared circuit." INDEX { x25ClearedCircuitIndex } ::= { x25ClearedCircuitTable 1 } X25ClearedCircuitEntry ::= SEQUENCE { x25ClearedCircuitIndex PositiveInteger, x25ClearedCircuitPleIndex IfIndexType, x25ClearedCircuitTimeEstablished TimeTicks, x25ClearedCircuitTimeCleared TimeTicks, x25ClearedCircuitChannel INTEGER, x25ClearedCircuitClearingCause INTEGER, x25ClearedCircuitDiagnosticCode INTEGER, x25ClearedCircuitInPdus Counter, x25ClearedCircuitOutPdus Counter, x25ClearedCircuitCalledAddress X121Address, x25ClearedCircuitCallingAddress X121Address, x25ClearedCircuitClearFacilities OCTET STRING } x25ClearedCircuitIndex OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely distinguishes one entry in the clearedCircuitTable from another. This index will start at 2147483647 and will decrease by one for each new entry added to the table. Upon reaching one, the index will reset to 2147483647. Because the index starts at 2147483647 and decreases, a manager may do a getnext on entry zero and obtain the most recent entry. When the index has the value of 1, the next entry will delete all entries in the table and that entry will be numbered 2147483647." ::= { x25ClearedCircuitEntry 1 } x25ClearedCircuitPleIndex OBJECT-TYPE SYNTAX IfIndexType ACCESS read-only STATUS mandatory DESCRIPTION "The value of ifIndex for the PLE which cleared the circuit that created the entry." ::= { x25ClearedCircuitEntry 2 } x25ClearedCircuitTimeEstablished OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the circuit was established. This will be the same value that was in the x25CircuitEstablishTime for the circuit." ::= { x25ClearedCircuitEntry 3 } x25ClearedCircuitTimeCleared OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the circuit was cleared. For locally initiated clears, this will be the time when the clear confirmation was received. For remotely initiated clears, this will be the time when the clear indication was received." ::= { x25ClearedCircuitEntry 4 } x25ClearedCircuitChannel OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The channel number for the circuit that was cleared." ::= { x25ClearedCircuitEntry 5 } x25ClearedCircuitClearingCause OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The Clearing Cause from the clear request or clear indication packet that cleared the circuit." REFERENCE "See ISO 8208 Section 12.2.3.1.1" ::= { x25ClearedCircuitEntry 6 } x25ClearedCircuitDiagnosticCode OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The Diagnostic Code from the clear request or clear indication packet that cleared the circuit." REFERENCE "See ISO 8208 Section 12.2.3.1.2" ::= { x25ClearedCircuitEntry 7 } x25ClearedCircuitInPdus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PDUs received on the circuit." ::= { x25ClearedCircuitEntry 8 } x25ClearedCircuitOutPdus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PDUs transmitted on the circuit." ::= { x25ClearedCircuitEntry 9 } x25ClearedCircuitCalledAddress OBJECT-TYPE SYNTAX X121Address ACCESS read-only STATUS mandatory DESCRIPTION "The called address from the cleared circuit." ::= { x25ClearedCircuitEntry 10 } x25ClearedCircuitCallingAddress OBJECT-TYPE SYNTAX X121Address ACCESS read-only STATUS mandatory DESCRIPTION "The calling address from the cleared circuit." ::= { x25ClearedCircuitEntry 11 } x25ClearedCircuitClearFacilities OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..109)) ACCESS read-only STATUS mandatory DESCRIPTION "The facilities field from the clear request or clear indication packet that cleared the circuit. A size of zero indicates no facilities were present." ::= { x25ClearedCircuitEntry 12 } -- ########################################################### -- The Call Parameter Table -- ########################################################### x25CallParmTable OBJECT-TYPE SYNTAX SEQUENCE OF X25CallParmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "These objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of these tables for the entire system. The indexes for the entries are independent of any PLE or any circuit. Other tables reference entries in this table. Entries in this table can be used for default PLE parameters, for parameters to use to place/answer a call, for the parameters currently in use for a circuit, or parameters that were used by a circuit. The number of references to a given set of parameters can be found in the x25CallParmRefCount object sharing the same instance identifier with the parameters. The value of this reference count also affects the access of the objects in this table. An object in this table with the same instance identifier as the instance identifier of an x25CallParmRefCount must be consider associated with that reference count. An object with an associated reference count of zero can be written (if its ACCESS clause allows it). An object with an associated reference count greater than zero can not be written (regardless of the ACCESS clause). This ensures that a set of call parameters being referenced from another table can not be modified or changed in a ways inappropriate for continued use by that table." ::= { x25 9 } x25CallParmEntry OBJECT-TYPE SYNTAX X25CallParmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries of x25CallParmTable." INDEX { x25CallParmIndex } ::= { x25CallParmTable 1 } X25CallParmEntry ::= SEQUENCE { x25CallParmIndex PositiveInteger, x25CallParmStatus EntryStatus, x25CallParmRefCount PositiveInteger, x25CallParmInPacketSize INTEGER, x25CallParmOutPacketSize INTEGER, x25CallParmInWindowSize INTEGER, x25CallParmOutWindowSize INTEGER, x25CallParmAcceptReverseCharging INTEGER, x25CallParmProposeReverseCharging INTEGER, x25CallParmFastSelect INTEGER, x25CallParmInThruPutClasSize INTEGER, x25CallParmOutThruPutClasSize INTEGER, x25CallParmCug DisplayString, x25CallParmCugoa DisplayString, x25CallParmBcug DisplayString, x25CallParmNui OCTET STRING, x25CallParmChargingInfo INTEGER, x25CallParmRpoa DisplayString, x25CallParmTrnstDly INTEGER, x25CallParmCallingExt DisplayString, x25CallParmCalledExt DisplayString, x25CallParmInMinThuPutCls INTEGER, x25CallParmOutMinThuPutCls INTEGER, x25CallParmEndTrnsDly OCTET STRING, x25CallParmPriority OCTET STRING, x25CallParmProtection DisplayString, x25CallParmExptData INTEGER, x25CallParmUserData OCTET STRING, x25CallParmCallingNetworkFacilities OCTET STRING, x25CallParmCalledNetworkFacilities OCTET STRING } x25CallParmIndex OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "A value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossible to know which other objects in the MIB reference entries in the table by looking at this table. Because of this, changes to parameters must be accomplished by creating a new entry in this table and then changing the referencing table to identify the new entry. Note that an agent will only use the values in this table when another table is changed to reference those values. The number of other tables that reference an index object in this table can be found in x25CallParmRefCount. The value of the reference count will affect the writability of the objects as explained above. Entries in this table which have a reference count of zero maybe deleted at the convence of the agent. Care should be taken by the agent to give the NMS sufficient time to create a reference to newly created entries. Should a Management Station not find a free index with which to create a new entry, it may feel free to delete entries with a reference count of zero. However in doing so the Management Station much realize it may impact other Management Stations." ::= { x25CallParmEntry 1 } x25CallParmStatus OBJECT-TYPE SYNTAX EntryStatus ACCESS read-write STATUS mandatory DESCRIPTION "The status of this call parameter entry. See RFC 1271 for details of usage." ::= { x25CallParmEntry 2 } x25CallParmRefCount OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value of, and will return a value of, the index for this set of call parameters. Examples of such objects are the x25AdmnDefCallParamId, x25OperDataLinkId, or x25AdmnDefCallParamId objects defined above." ::= { x25CallParmEntry 3 } x25CallParmInPacketSize OBJECT-TYPE SYNTAX INTEGER (0..4096) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a default size of 128." REFERENCE "10733 proposedPacketSize; See ISO 8208 Section 15.2.2.1.1" DEFVAL { 128 } ::= { x25CallParmEntry 4 } x25CallParmOutPacketSize OBJECT-TYPE SYNTAX INTEGER (0..4096) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use a default size of 128." REFERENCE "10733 proposedPacketSize; See ISO 8208 Section 15.2.2.1.1" DEFVAL { 128 } ::= { x25CallParmEntry 5 } x25CallParmInWindowSize OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "The receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2." REFERENCE "10733 proposedWindowSize; See ISO 8208 Section 15.2.2.1.2" DEFVAL { 2 } ::= { x25CallParmEntry 6 } x25CallParmOutWindowSize OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "The transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2." REFERENCE "10733 proposedWindowSize; See ISO 8208 Section 15.2.2.1.2" DEFVAL { 2 } ::= { x25CallParmEntry 7 } x25CallParmAcceptReverseCharging OBJECT-TYPE SYNTAX INTEGER { default (1), accept (2), refuse (3), neverAccept (4) } ACCESS read-write STATUS mandatory DESCRIPTION "An enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of neverAccept is only used for the PLE default and indicates the PLE will never accept reverse charging. A value of default for a PLE default means refuse." REFERENCE "10733 acceptReverseCharging" DEFVAL { refuse } ::= { x25CallParmEntry 8 } x25CallParmProposeReverseCharging OBJECT-TYPE SYNTAX INTEGER { default (1), reverse (2), local (3) } ACCESS read-write STATUS mandatory DESCRIPTION "An enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default for the PLE default means use local." REFERENCE "10733 proposedPacketSize; See ISO 8208 Section 15.2.2.6" DEFVAL { local } ::= { x25CallParmEntry 9 } x25CallParmFastSelect OBJECT-TYPE SYNTAX INTEGER { default (1), notSpecified (2), fastSelect (3), restrictedFastResponse (4), noFastSelect (5), noRestrictedFastResponse (6) } ACCESS read-write STATUS mandatory DESCRIPTION "Expresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means noFastSelect. A value of noFastSelect or noRestrictedFastResponse indicates a circuit may not use fast select or restricted fast response." REFERENCE "10733 fastSelect; Sec ISO 8208 Section 15.2.2.6" DEFVAL { noFastSelect } ::= { x25CallParmEntry 10 } x25CallParmInThruPutClasSize OBJECT-TYPE SYNTAX INTEGER { tcReserved1 (1), tcReserved2 (2), tc75 (3), tc150 (4), tc300 (5), tc600 (6), tc1200 (7), tc2400 (8), tc4800 (9), tc9600 (10), tc19200 (11), tc48000 (12), tc64000 (13), tcReserved14 (14), tcReserved15 (15), tcReserved0 (16), tcNone (17), tcDefault (18) } ACCESS read-write STATUS mandatory DESCRIPTION "The incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone. A value of tcNone means do not negotiate throughtput class." REFERENCE "See ISO 8208 Section 15.2.2.2, table 18" DEFVAL { tcNone } ::= { x25CallParmEntry 11 } x25CallParmOutThruPutClasSize OBJECT-TYPE SYNTAX INTEGER { tcReserved1 (1), tcReserved2 (2), tc75 (3), tc150 (4), tc300 (5), tc600 (6), tc1200 (7), tc2400 (8), tc4800 (9), tc9600 (10), tc19200 (11), tc48000 (12), tc64000 (13), tcReserved14 (14), tcReserved15 (15), tcReserved0 (16), tcNone (17), tcDefault (18) } ACCESS read-write STATUS mandatory DESCRIPTION "The outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tcNone. A value of tcNone means do not negotiate throughtput class." REFERENCE "See ISO 8208 Section 15.2.2.2, table 18" DEFVAL { tcNone } ::= { x25CallParmEntry 12 } x25CallParmCug OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) ACCESS read-write STATUS mandatory DESCRIPTION "The Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility requested. A string length of three containing the characters DEF for a circuit means use the PLE default, (the PLE default parameter may not reference an entry of DEF.)" REFERENCE "See ISO 8208 Section 15.2.2.3" DEFVAL { ''h } ::= { x25CallParmEntry 13 } x25CallParmCugoa OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) ACCESS read-write STATUS mandatory DESCRIPTION "The Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameters may not reference an entry of DEF). A zero length string indicates no facility requested." REFERENCE "See ISO 8208 Section 15.2.2.4" DEFVAL { ''h } ::= { x25CallParmEntry 14 } x25CallParmBcug OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "The Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameter may not reference an entry of DEF). A zero length string indicates no facility requested." REFERENCE "See ISO 8208 Section 15.2.2.5" DEFVAL { ''h } ::= { x25CallParmEntry 15 } x25CallParmNui OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..108)) ACCESS read-write STATUS mandatory DESCRIPTION "The Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero length string indicates no facility requested. This value is ignored for the PLE default parameters entry." REFERENCE "See ISO 8208 Section 15.2.2.7" DEFVAL { ''h } ::= { x25CallParmEntry 16 } x25CallParmChargingInfo OBJECT-TYPE SYNTAX INTEGER { default (1), noFacility (2), noChargingInfo (3), chargingInfo (4) } ACCESS read-write STATUS mandatory DESCRIPTION "The charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use noFacility. The value of noFacility means do not include a facility." REFERENCE "See ISO 8208 Section 15.2.2.8" DEFVAL { noFacility } ::= { x25CallParmEntry 17 } x25CallParmRpoa OBJECT-TYPE SYNTAX DisplayString (SIZE(0..108)) ACCESS read-write STATUS mandatory DESCRIPTION "The RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 characters DEF for a circuit specifies use of the PLE default (the entry for the PLE default may not contain DEF). A zero length string indicates no facility requested." REFERENCE "See ISO 8208, section 15.2.2.9" DEFVAL { ''h } ::= { x25CallParmEntry 18 } x25CallParmTrnstDly OBJECT-TYPE SYNTAX INTEGER (0..65537) ACCESS read-write STATUS mandatory DESCRIPTION "The Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (the PLE default parameters entry may not use the value 65537). The value 65535 may only be used to indicate the value in use by a circuit." REFERENCE "See ISO 8208, Section 15.2.2.13" DEFVAL { 65536 } ::= { x25CallParmEntry 19 } -- The following parameters are for CCITT facilities. x25CallParmCallingExt OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) ACCESS read-write STATUS mandatory DESCRIPTION "The Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested." REFERENCE "See ISO 8208 Section 15.3.2.1" DEFVAL { ''h } ::= { x25CallParmEntry 20 } x25CallParmCalledExt OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) ACCESS read-write STATUS mandatory DESCRIPTION "The Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested." REFERENCE "See ISO 8208 Section 15.3.2.2" DEFVAL { ''h } ::= { x25CallParmEntry 21 } x25CallParmInMinThuPutCls OBJECT-TYPE SYNTAX INTEGER (0..17) ACCESS read-write STATUS mandatory DESCRIPTION "The minimum input throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested." REFERENCE "See ISO 8208 Section 15.3.2.3" DEFVAL { 17 } ::= { x25CallParmEntry 22 } x25CallParmOutMinThuPutCls OBJECT-TYPE SYNTAX INTEGER (0..17) ACCESS read-write STATUS mandatory DESCRIPTION "The minimum output throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested." REFERENCE "See ISO 8208 Section 15.3.2.3" DEFVAL { 17 } ::= { x25CallParmEntry 23 } x25CallParmEndTrnsDly OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..6)) ACCESS read-write STATUS mandatory DESCRIPTION "The End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An octet string of length 3 containing the three character DEF for a circuit means use the PLE default (the entry for the PLE default can not contain the characters DEF). A zero length string indicates no facility requested." REFERENCE "See ISO 8208 Section 15.3.2.4" DEFVAL { ''h } ::= { x25CallParmEntry 24 } x25CallParmPriority OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..6)) ACCESS read-write STATUS mandatory DESCRIPTION "The priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requested. The entry for the PLE default parameters must be zero length." REFERENCE "See ISO 8208 Section 15.3.2.5" DEFVAL { ''h } ::= { x25CallParmEntry 25 } x25CallParmProtection OBJECT-TYPE SYNTAX DisplayString (SIZE(0..108)) ACCESS read-write STATUS mandatory DESCRIPTION "A string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the packet by the agent. The agent will supply the length field and the length octet is not contained in this string. An string containing the 3 characters DEF for a circuit means use the PLE default (the entry for the PLE default parameters may not use the value DEF). A zero length string mean no facility requested." REFERENCE "See ISO 8208 Section 15.3.2.5" DEFVAL { ''h } ::= { x25CallParmEntry 26 } x25CallParmExptData OBJECT-TYPE SYNTAX INTEGER { default (1), noExpeditedData (2), expeditedData (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not have the value default." REFERENCE "See ISO 8208 Section 15.3.2.7" DEFVAL { noExpeditedData } ::= { x25CallParmEntry 27 } x25CallParmUserData OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) ACCESS read-write STATUS mandatory DESCRIPTION "The call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call user data defined, the data from the circuit call parameters will be used. If only the PLE has data defined, the PLE entry will be used. If neither the circuit call parameters or the PLE default entry has a value, no call user data will be sent." REFERENCE "See ISO 8208 Section 12.2.1.1.6, 12.2.1.2" DEFVAL { ''h } ::= { x25CallParmEntry 28 } x25CallParmCallingNetworkFacilities OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..108)) ACCESS read-write STATUS mandatory DESCRIPTION "The calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities." REFERENCE "See ISO 8206 Section 15.1, category b" DEFVAL { ''h } ::= { x25CallParmEntry 29 } x25CallParmCalledNetworkFacilities OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..108)) ACCESS read-write STATUS mandatory DESCRIPTION "The called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities." REFERENCE "See ISO 8206 Section 15.1, category c" DEFVAL { ''h } ::= { x25CallParmEntry 30 } -- ########################################################### -- X.25 Traps -- ########################################################### x25Restart TRAP-TYPE ENTERPRISE x25 VARIABLES { x25OperIndex } DESCRIPTION "This trap means the X.25 PLE sent or received a restart packet. The restart that brings up the link should not send a x25Restart trap so the interface should send a linkUp trap. Sending this trap means the agent does not send a linkDown and linkUp trap." ::= 1 x25Reset TRAP-TYPE ENTERPRISE x25 VARIABLES { x25CircuitIndex, x25CircuitChannel } DESCRIPTION "If the PLE sends or receives a reset, the agent should send an x25Reset trap." ::= 2 -- ########################################################### -- X.25 Protocol Version Identifiers -- ########################################################### x25ProtocolVersion OBJECT IDENTIFIER ::= { x25 10 } -- X.25 CCITT 1976 version. x25protocolCcittV1976 OBJECT IDENTIFIER ::= { x25ProtocolVersion 1 } -- X.25 CCITT 1980 version. x25protocolCcittV1980 OBJECT IDENTIFIER ::= { x25ProtocolVersion 2 } -- X.25 CCITT 1984 version. x25protocolCcittV1984 OBJECT IDENTIFIER ::= { x25ProtocolVersion 3 } -- X.25 CCITT 1988 version. x25protocolCcittV1988 OBJECT IDENTIFIER ::= { x25ProtocolVersion 4 } -- X.25 1987 version of ISO 8208. x25protocolIso8208V1987 OBJECT IDENTIFIER ::= { x25ProtocolVersion 5 } -- X.25 1989 version of ISO 8208. x25protocolIso8208V1989 OBJECT IDENTIFIER ::= { x25ProtocolVersion 6 } -- ########################################################### END