Server : Apache System : Linux server1.cgrithy.com 3.10.0-1160.95.1.el7.x86_64 #1 SMP Mon Jul 24 13:59:37 UTC 2023 x86_64 User : nobody ( 99) PHP Version : 8.1.23 Disable Function : NONE Directory : /usr/share/mibs/ietf/ |
T11-FC-RSCN-MIB DEFINITIONS ::= BEGIN -- The Fibre Channel RSCN MIB -- -- for the monitoring of registrations by Nx_Ports to receive -- Registered State Change Notifications (RSCNs), and the -- monitoring of RSCN usage. -- IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Counter32, mib-2 FROM SNMPv2-SMI -- [RFC2578] MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF -- [RFC2580] TruthValue FROM SNMPv2-TC -- [RFC2579] fcmInstanceIndex, fcmSwitchIndex, FcNameIdOrZero, FcAddressIdOrZero FROM FC-MGMT-MIB -- [RFC4044] T11NsGs4RejectReasonCode FROM T11-FC-NAME-SERVER-MIB -- [RFC4438] T11FabricIndex FROM T11-TC-MIB; -- [RFC4439] t11FcRscnMIB MODULE-IDENTITY LAST-UPDATED "200701080000Z" ORGANIZATION "For the initial versions, T11. For later versions, the IETF's IMSS Working Group." CONTACT-INFO " Claudio DeSanti Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134 USA EMail: cds@cisco.com Keith McCloghrie Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134 USA EMail: kzm@cisco.com" DESCRIPTION "The MIB module for the management of registrations by Nx_Ports to receive RSCNs (Registered State Change Notifications) on a Fibre Channel Fabric, as defined in FC-LS, and for the monitoring of RSCNs sent/received or rejected in a Fibre Channel Fabric. Copyright (C) The Internet Society (2007). This version of this MIB module is part of RFC 4983; see the RFC itself for full legal notices." REVISION "200701080000Z" DESCRIPTION "Initial version of this MIB module, published as RFC 4983." ::= { mib-2 161 } t11FcRscnNotifications OBJECT IDENTIFIER ::= { t11FcRscnMIB 0 } t11FcRscnObjects OBJECT IDENTIFIER ::= { t11FcRscnMIB 1 } t11FcRscnConformance OBJECT IDENTIFIER ::= { t11FcRscnMIB 2 } t11FcRscnRegistrations OBJECT IDENTIFIER ::= { t11FcRscnObjects 1 } t11FcRscnStats OBJECT IDENTIFIER ::= { t11FcRscnObjects 2 } t11FcRscnInformation OBJECT IDENTIFIER ::= { t11FcRscnObjects 3 } -- State Change Registration Table t11FcRscnRegTable OBJECT-TYPE SYNTAX SEQUENCE OF T11FcRscnRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Nx_Ports that have registered to receive RSCNs on all Fabrics configured on one or more Fibre Channel switches." ::= { t11FcRscnRegistrations 1 } t11FcRscnRegEntry OBJECT-TYPE SYNTAX T11FcRscnRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information about one Nx_Port that has registered with a particular switch (identified by values of fcmInstanceIndex and fcmSwitchIndex) for a particular Fabric (identified by a t11FcRscnFabricIndex value)." INDEX { fcmInstanceIndex, fcmSwitchIndex, t11FcRscnFabricIndex, t11FcRscnRegFcId } ::= { t11FcRscnRegTable 1 } T11FcRscnRegEntry ::= SEQUENCE { t11FcRscnFabricIndex T11FabricIndex, t11FcRscnRegFcId FcAddressIdOrZero, t11FcRscnRegType BITS } t11FcRscnFabricIndex OBJECT-TYPE SYNTAX T11FabricIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index value that uniquely identifies a particular Fabric. In a Fabric conformant to FC-SW-4, multiple Virtual Fabrics can operate within one (or more) physical infrastructures. In such a case, this index value is used to uniquely identify a particular Fabric within a physical infrastructure. In a Fabric that has (or can have) only a single Fabric operating within the physical infrastructure, the value of this Fabric Index will always be 1." REFERENCE "ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4 (FC-SW-4), December 2006." ::= { t11FcRscnRegEntry 1 } t11FcRscnRegFcId OBJECT-TYPE SYNTAX FcAddressIdOrZero (SIZE (3)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Fibre Channel Address Identifier of the registering Nx_Port." ::= { t11FcRscnRegEntry 2 } t11FcRscnRegType OBJECT-TYPE SYNTAX BITS { fromFabricController(0), fromNxPort(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the type of registration desired by the registering Nx_Port, one bit per type: 'fromFabricController' -- RSCNs generated for events detected by the Fabric Controller. 'fromNxPorts' -- RSCNs generated for events detected by the affected Nx_Port." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 40." ::= { t11FcRscnRegEntry 3 } -- Statistics t11FcRscnStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF T11FcRscnStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RSCN-related statistics on all Fabrics configured on one or more Fibre Channel switches. Two levels of statistics are included: 1) counters at the message-type level, for: - the number of SCRs received/rejected, - the number of RSCNs sent/received/rejected, - the number of SW_RSCNs sent/received/rejected. 2) counters of sent/received RSCNs per 'Event Qualifier' value. Note that if and when several RSCN events are coalesced into a single RSCN message, then that message may be counted in more than one of these counters." ::= { t11FcRscnStats 1 } t11FcRscnStatsEntry OBJECT-TYPE SYNTAX T11FcRscnStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing statistics for a particular Fabric (identified by a t11FcRscnFabricIndex value) on a particular switch (identified by values of fcmInstanceIndex and fcmSwitchIndex)." INDEX { fcmInstanceIndex, fcmSwitchIndex, t11FcRscnFabricIndex } ::= { t11FcRscnStatsTable 1 } T11FcRscnStatsEntry ::= SEQUENCE { t11FcRscnInScrs Counter32, t11FcRscnInRscns Counter32, t11FcRscnOutRscns Counter32, t11FcRscnInSwRscns Counter32, t11FcRscnOutSwRscns Counter32, t11FcRscnScrRejects Counter32, t11FcRscnRscnRejects Counter32, t11FcRscnSwRscnRejects Counter32, t11FcRscnInUnspecifiedRscns Counter32, t11FcRscnOutUnspecifiedRscns Counter32, t11FcRscnInChangedAttribRscns Counter32, t11FcRscnOutChangedAttribRscns Counter32, t11FcRscnInChangedServiceRscns Counter32, t11FcRscnOutChangedServiceRscns Counter32, t11FcRscnInChangedSwitchRscns Counter32, t11FcRscnOutChangedSwitchRscns Counter32, t11FcRscnInRemovedRscns Counter32, t11FcRscnOutRemovedRscns Counter32 } t11FcRscnInScrs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SCRs received from Nx_Ports by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 1 } t11FcRscnInRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RSCNs received from Nx_Ports by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 2 } t11FcRscnOutRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RSCNs transmitted to Nx_Ports by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 3 } t11FcRscnInSwRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SW_RSCNs received by this switch from other switches on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 4 } t11FcRscnOutSwRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SW_RSCNs transmitted by this switch from other switches on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 5 } t11FcRscnScrRejects OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SCRs rejected by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 6 } t11FcRscnRscnRejects OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RSCNs rejected by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 7 } t11FcRscnSwRscnRejects OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SW_RSCN rejected by this switch on this Fabric. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." ::= { t11FcRscnStatsEntry 8 } t11FcRscnInUnspecifiedRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) received by this switch on this Fabric which contained an RSCN Event Qualifier value of '0000'b meaning 'Event is not specified'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 9 } t11FcRscnOutUnspecifiedRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) sent by this switch on this Fabric which contained an RSCN Event Qualifier value of '0000'b meaning 'Event is not specified'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 10 } t11FcRscnInChangedAttribRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) received by this switch on this Fabric which contained an RSCN Event Qualifier value of '0002'b meaning 'Changed Port Attribute'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 11 } t11FcRscnOutChangedAttribRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) sent by this switch on this Fabric which contained an RSCN Event Qualifier value of '0002'b meaning 'Changed Port Attribute'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 12 } t11FcRscnInChangedServiceRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) received by this switch on this Fabric which contained an RSCN Event Qualifier value of '0003'b meaning 'Changed Service Object'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 13 } t11FcRscnOutChangedServiceRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) sent by this switch on this Fabric which contained an RSCN Event Qualifier value of '0003'b meaning 'Changed Service Object'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 14 } t11FcRscnInChangedSwitchRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) received by this switch on this Fabric which contained an RSCN Event Qualifier value of '0004'b meaning 'Changed Switch Configuration'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 15 } t11FcRscnOutChangedSwitchRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) sent by this switch on this Fabric which contained an RSCN Event Qualifier value of '0004'b meaning 'Changed Switch Configuration'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 16 } t11FcRscnInRemovedRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) received by this switch on this Fabric which contained an RSCN Event Qualifier value of '0005'b meaning 'Removed Object'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 17 } t11FcRscnOutRemovedRscns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Registered State Change Notifications (RSCNs) sent by this switch on this Fabric which contained an RSCN Event Qualifier value of '0005'b meaning 'Removed Object'. This counter has no discontinuities other than those that all Counter32s have when sysUpTime=0." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 36." ::= { t11FcRscnStatsEntry 18 } -- -- Notification Control Table -- t11FcRscnNotifyControlTable OBJECT-TYPE SYNTAX SEQUENCE OF T11FcRscnNotifyControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of control information for notifications generated due to the rejection of an SCR or RSCN." ::= { t11FcRscnInformation 1 } t11FcRscnNotifyControlEntry OBJECT-TYPE SYNTAX T11FcRscnNotifyControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains notification control information concerning the rejection of RSCN/SCRs for a particular Fabric (identified by the value of t11FcRscnFabricIndex) by a particular switch (identified by values of fcmInstanceIndex and fcmSwitchIndex)." INDEX { fcmInstanceIndex, fcmSwitchIndex, t11FcRscnFabricIndex } ::= { t11FcRscnNotifyControlTable 1 } T11FcRscnNotifyControlEntry ::= SEQUENCE { t11FcRscnIlsRejectNotifyEnable TruthValue, t11FcRscnElsRejectNotifyEnable TruthValue, t11FcRscnRejectedRequestString OCTET STRING, t11FcRscnRejectedRequestSource FcNameIdOrZero, t11FcRscnRejectReasonCode T11NsGs4RejectReasonCode, t11FcRscnRejectReasonCodeExp OCTET STRING, t11FcRscnRejectReasonVendorCode OCTET STRING } t11FcRscnIlsRejectNotifyEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies if a t11FcRscnIlsRejectReqNotify notification should be generated when this switch rejects an SW_RSCN on this Fabric. Values written to this object should be retained over agent reboots." DEFVAL { false } ::= { t11FcRscnNotifyControlEntry 1 } t11FcRscnElsRejectNotifyEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies if a t11FcRscnElsRejectReqNotify notification should be generated when this switch rejects an RSCN or SCR on this Fabric. Values written to this object should be retained over agent reboots." DEFVAL { false } ::= { t11FcRscnNotifyControlEntry 2 } t11FcRscnRejectedRequestString OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The binary content of the RSCN, SCR, or SW_RSCN that was most recently rejected by this switch on this Fabric. The value is formatted as an octet string (in network byte order) as described in the relevant Fibre Channel standard, containing the payload (which is typically a list of affected ports and error codes) of the rejected RSCN or SCR as described in FC-LS, or the rejected SW_RSCN as described in FC-SW-4. This object contains the zero-length string if and when the RSCN/SCR/SW_RSCN payload is unavailable. When the length of this object is 255 octets, it contains the first 255 octets of the payload (in network byte order)." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Tables 34 & 39. ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4 (FC-SW-4), December 2006, Table 45." ::= { t11FcRscnNotifyControlEntry 3 } t11FcRscnRejectedRequestSource OBJECT-TYPE SYNTAX FcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The WWN that was the source of the RSCN, SCR, or SW_RSCN that was most recently rejected by this switch on this Fabric." ::= { t11FcRscnNotifyControlEntry 4 } t11FcRscnRejectReasonCode OBJECT-TYPE SYNTAX T11NsGs4RejectReasonCode MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the Reason Code of the most recent rejection by this switch of an RSCN, SCR or SW_RSCN on this Fabric." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 146. ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4 (FC-SW-4), December 2006, Table 5." ::= { t11FcRscnNotifyControlEntry 5 } t11FcRscnRejectReasonCodeExp OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the Reason Code Explanation of the most recent rejection by this switch of an RSCN, SCR or SW_RSCN on this Fabric." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 147. ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4 (FC-SW-4), December 2006, Table 6." ::= { t11FcRscnNotifyControlEntry 6 } t11FcRscnRejectReasonVendorCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the Reason Vendor Specific Code of the most recent rejection by this switch of an RSCN, SCR or SW_RSCN on this Fabric." REFERENCE "ANSI INCITS 433-2007, Fibre Channel - Link Services (FC-LS), July 2007, Table 148. ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4 (FC-SW-4), December 2006, Section 6.1.3." ::= { t11FcRscnNotifyControlEntry 7 } -- Notifications t11FcRscnElsRejectReqNotify NOTIFICATION-TYPE OBJECTS { t11FcRscnRejectedRequestString, t11FcRscnRejectedRequestSource, t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp, t11FcRscnRejectReasonVendorCode } STATUS current DESCRIPTION "This notification is generated when a switch rejects an SCR or RSCN. The value of t11FcRscnRejectedRequestString indicates the binary content of the rejected request if available, or the zero-length string otherwise. The source of the rejected request is given by t11FcRscnRejectedRequestSource, and the reason for rejection is given by the values of t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp and t11FcRscnRejectReasonVendorCode." ::= { t11FcRscnNotifications 1 } t11FcRscnIlsRejectReqNotify NOTIFICATION-TYPE OBJECTS { t11FcRscnRejectedRequestString, t11FcRscnRejectedRequestSource, t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp, t11FcRscnRejectReasonVendorCode } STATUS current DESCRIPTION "This notification is generated when a switch rejects an SW_RSCN. The value of t11FcRscnRejectedRequestString indicates the binary content of the rejected request if available, or the zero-length string otherwise. The source of the rejected request is given by t11FcRscnRejectedRequestSource, and the reason for rejection is given by the values of t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp and t11FcRscnRejectReasonVendorCode." ::= { t11FcRscnNotifications 2 } -- Conformance t11FcRscnCompliances OBJECT IDENTIFIER ::= { t11FcRscnConformance 1 } t11FcRscnGroups OBJECT IDENTIFIER ::= { t11FcRscnConformance 2 } t11FcRscnCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities that implement this MIB." MODULE MANDATORY-GROUPS { t11FcRscnRegistrationGroup, t11FcRscnNotifyControlGroup, t11FcRscnNotifyGroup } GROUP t11FcRscnStatsGroup DESCRIPTION "These counters, containing RSCN-related statistics, are mandatory only for those systems that count such events." OBJECT t11FcRscnIlsRejectNotifyEnable MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT t11FcRscnElsRejectNotifyEnable MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { t11FcRscnCompliances 1 } -- Units of conformance t11FcRscnRegistrationGroup OBJECT-GROUP OBJECTS { t11FcRscnRegType } STATUS current DESCRIPTION "A collection of objects for monitoring RSCN registrations." ::= { t11FcRscnGroups 1 } t11FcRscnStatsGroup OBJECT-GROUP OBJECTS { t11FcRscnInScrs, t11FcRscnInRscns, t11FcRscnOutRscns, t11FcRscnInSwRscns, t11FcRscnOutSwRscns, t11FcRscnScrRejects, t11FcRscnRscnRejects, t11FcRscnSwRscnRejects, t11FcRscnInUnspecifiedRscns, t11FcRscnOutUnspecifiedRscns, t11FcRscnInChangedAttribRscns, t11FcRscnOutChangedAttribRscns, t11FcRscnInChangedServiceRscns, t11FcRscnOutChangedServiceRscns, t11FcRscnInChangedSwitchRscns, t11FcRscnOutChangedSwitchRscns, t11FcRscnInRemovedRscns, t11FcRscnOutRemovedRscns } STATUS current DESCRIPTION "A collection of objects for collecting RSCN-related statistics." ::= { t11FcRscnGroups 2 } t11FcRscnNotifyControlGroup OBJECT-GROUP OBJECTS { t11FcRscnIlsRejectNotifyEnable, t11FcRscnElsRejectNotifyEnable, t11FcRscnRejectedRequestString, t11FcRscnRejectedRequestSource, t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp, t11FcRscnRejectReasonVendorCode } STATUS current DESCRIPTION "A collection of notification control and notification information objects." ::= { t11FcRscnGroups 3 } t11FcRscnNotifyGroup NOTIFICATION-GROUP NOTIFICATIONS { t11FcRscnIlsRejectReqNotify, t11FcRscnElsRejectReqNotify } STATUS current DESCRIPTION "A collection of notifications for monitoring ILS and ELS rejections by the RSCN module." ::= { t11FcRscnGroups 4 } END